Skip to main content

Table 2 Predictors of task performance in the AR environment

From: The impact of visuospatial perception on distance judgment and depth perception in an Augmented Reality environment in patients after stroke: an exploratory study

 

Patients

Healthy subjects

PMT

AFCT

PT

PMT

AFCT

PT

Total

 Stereovision

(0.116)

(− 0.616)

 − 0.236

 − 0.463

 − 0.092

0.139

 Quality of stereovision

(− 0.023)

(− 0.527)

0.268

 − 1.189**

0.709*

0.879**

 Spatial localization/visuoconstruction

(− 0.407)

(0.246)

0.423

 − 0.041

 − 0.085

 − 0.277

ADL

 Stereovision

(− 0.073)

(− 0.217)

(0.091)

 − 0.561

0.135

0.392

 Quality of stereovision

(− 0.084)

(− 0.263)

(0.414)

 − 1.173**

0.770*

1.150**

 Spatial localization/visuoconstruction

(− 0.252)

(− 0.323)

(0.118)

0.028

0.231

 − 0.218

Geometric

 Stereovision

0.002

(− 0.955)

 − 0.450

 − 0.117

(− 0.277)

(− 0.463)

 Quality of stereovision

 − 0.401

(− 0.862)

0.101

 − 0.731

(0.193)

(− 0.108)

 Spatial localization/visuoconstruction

 − 0.508*

(0.271)

0.533**

 − 0.218

(− 0.232)

(− 0.271)

  1. Cells present β-coefficients of each predictor.*significant predictor at p < 0.05, **significant predictor at p < 0.01, (): model did not significantly predict task performance, ADL: Activities of Daily Living, AFCT: Alternative Forced Choice Task, PMT: Perceptual Matching Task, PT: Position Task, Spatial localization/Visuoconstruction: VOSP test battery, Quality of stereovision: Circles test, Stereovision: stereoimpaired stereointact