Table 2 Comparison of main selectivity study platforms found in literature

From: Advances in selective activation of muscles for non-invasive motor neuroprostheses

Platform

Lawrence et al., 2006 [54]

O'Dwyer et al., 2006 [56]

Popovic et al, 2009 [57]

Malesevic et. al, 2010 [58]

Malesevic et al, 2012 [59]

Schill et al, 2009 [60]

Chen et al, 2007 [45]

Koutsou et al, 2013 [61]

Exell et al, 2013 [62]

Array Electrode

Smart Electrode 64-pads

2 x 2 round

Actitrode, 24-pads, round

INTFES, 16-pads, oval

INTFES, 16-pads, oval

2x3 round

own electrode array

Smartex electrode array

FEA, 4x6 round

Electrical stimulator

Compex Motion2. 4-channel biphasic asymmetric

Neurotech NT2000, 6-channel biphasic asymmetric

UNAFET, 4-channel biphasic asymmetric

INTEFES, 1-channel with a demultiplexer for 32-pad electrodes monophasic rectangular

INTEFES, 1-channel with a demultiplexer for 32-pad electrodes monophasic rectangular

MotionStim 8, 8-channel biphasic

NM III

INTEFES, 1-channel with a demultiplexer for 32-pad electrodes monophasic rectangular

Modified Odstock stimulator

Upper Limb functions

fingers' flexion

Wrist flexion-extension,abduction-aduction, Fingers's flexion

Forearm pronation-supination, wrist flexion-extension, abduction-adduction, fingers's flexion-extension

wrist flexion-extension, fingers' flexion-extension

wrist flexion-extension, fingers' flexion

wrist flexion-extension, abduction-adduction

Wrist joint, fingers' felxion-extension

Forearm pronation-supination, wrist flexion-extension, abduction-adduction, fingers's flexion-extension

Wrist joint, fingers' felxion-extension

Sensors

miniature load cells

bend sensors, accelelometers

goniometers

goniometers, accelelometers

bend sensors

bend sensors

CyberGlove

bend sensors, accelelometers

Data glove, twin-axis electrogoniometer

Stimulation Strategy

Sequentially activation of pads region during 5 s

Sequentially activation of a different combination of pair electrodes during 3 s

Sequentially activation of pads during 4 s

Single current pulses via each pad, with frequency of 2 Hz.

Sequentially activation of pads during 2 s

Single current pulses via each pad

Sequentially activation of pads

Sequentially activation of pads during 2 s

Sequentially activation of pads region(blocks)

Pad Selection

Automatic, regions with higher forces

Automatic, comparison with target movement

Automatic, cost function

Automatic, ANN

Automatic, cost function

semi-automatic, cost function

non-automatic, pas with higher amount of movement

Automatic, cost function

Automatic, ILC

Portability

NOT Portable

Portable

portable

portable

portable

portable

portable

portable

portable