Skip to main content
Figure 2 | Journal of NeuroEngineering and Rehabilitation

Figure 2

From: Study of stability of time-domain features for electromyographic pattern recognition

Figure 2

Examples of recorded EMG signals. (A) Comparison of raw EMG signals recorded during electrode location shift, effort level change, and muscle fatigue. (B) Comparison of power spectral density (PSD) of EMG signals with and without fatigue. The representative PSD was estimated using sampled data for elbow flexion. The effort level was set to low. Median frequencies are demonstrated by the vertical dashed lines. The median frequency is 60.4 Hz without muscle fatigue and is 50.8 Hz when the muscle is fatigue. The estimated signal power is 1.42 × 107 mV2 without muscle fatigue and is 1.46 × 107 mV2 with muscle fatigue.

Back to article page